Need to maximise productivity and efficiency when electrical safety testing?The Elite test system is Clare’s flagship product and features 11 powerful tests in one tester. These tests are: AC/DC flash/hipot, DC insulation resistance, earth/ground bond and leakage. The Elite is designed for automatic dual voltage (230V/115V, 50/60Hz) operation and is capable of testing product safety in accordance with most international safety standards and approvals agency recommendations – such as IEC, UL, CSA, VDE, EN, BEAB and BABT. The Elite has a simple friendly user interface, centring on a single button operation with the option to allow engineers and supervisors to create their own pre-programmed test sequence for each product. Powerful Windows software is bundled with this product to enable the tester to be effectively network connected. The 9024 and the 9024V variants of the Elite incorporate a test capability where the function output test voltage can be varied from 10 to 280V. The 9024 variant can also raise the function test output higher than the supply (up to 280V), making it ideal for product lab audit and conformance type testing. The Elite not only carries out electrical safety tests but can also act as the core within an automated test system. It does this by acting as a simple PLC controller and can control up to 8 external I/O devices, reading inputs and making analogue sensor measurements. Using the sophisticated PC software, traceable test results can be stored and SPC type analysis can be undertaken on the measured data. The Elite incorporates a fast interlock system to ensure that operators are not exposed to hazardous conditions, and the output ports can be configured to drive beacons and other warning or safety shutdown devices. The Elite is the professional solution for practically every manufacturing or conformance electrical safety testing application, facilitating high levels of automation and process control within the production and design environment. |
Earth/Ground Continuity Test
Test voltage: 12V AC nominal into an open circuit
Test current: 0 to 26A in steps of 1A
Test current accuracy: ±3%
Measurement range: 0 to 1.999Ω with a resolution of 0.001Ω
Measurement accuracy: ±2% of reading ±2 digits ±5mΩ
Test time: 0 to 255 seconds in steps of 1 second
Protection: thermal overload
Measurement system: 4 wire
Insulation Resistance Test
Test voltage: 200 to 1050V DC in steps of 5V
Test voltage accuracy: ±2%
Break point current: 1mA DC minimum
Short circuit current: 1.5 mA DC nominal
Capacitance drive: 1mF at 10MΩ
Measurement range: 0 to 20MΩ in steps of 10kΩ, 19MΩ to 199.99MΩ in steps of 0.1MΩ
Measurement accuracy: ±2% of reading ±2 digits
Test time: 0 to 255 seconds in steps of 1 second
DC Flash/HIPOT Test
Test voltage: 200V to 6kV DC in steps of 25V
Test voltage accuracy: ±2% ±20V
Test current: 10mA DC maximum
Capacitance drive: 1mF
Measurement range: 0 to 9.99mA with a resolution of 0.01mA
Measurement accuracy: ±2% of reading ±2 digits
Ramp time: 0.1 to 25 seconds in steps of 0.1 second
Dwell time: 0 to 255 seconds in steps of 1 second
Failure modes: breakdown (dv/dt > 10V/ms)
software trip (user selectable 0 - 9.99mA)
hardware trip (11mA nominal)
Discharge time: 2 seconds maximum
Shut down time: <20ms maximum
Phase Neutral Continuity Test
Test voltage: 9 Volts DC nominal into an open circuit
Test voltage accuracy: ±2%
Test current: 8mA DC short circuit
Measurement range: 0 to 1999Ω with a resolution of 1Ω
Measurement accuracy: ±2% of reading ±2 digits
Test time: 0 to 255 seconds in steps of 1 second
Protection: protection against connection to mains
Screen (100 mA Earth Continuity)
Test voltage: 250mV DC maximum into an open circuit
Test current: 100mA DC constant current
Test current accuracy: ±2%
Measurement range: 0 to 1.999Ω with a resolution of 0.001Ω
Accuracy: ±2% of reading ±2 digits
Test time: 0 to 255 seconds in steps of 1 second
Protection: protection against connection to mains
Measurement system: 4 wire
Analogue Test
Voltage input range: 0 to 12V
Measurement range: 0 to 11.99V with a resolution of 0.01V
Measurement accuracy: ±2% of reading ±2 digits
Test time: 1 to 255 seconds in steps of 1 second
Supply
Supply voltage: 230 Volts ±15% at 50 - 60Hz
Power consumption: 50VA maximum (standby) 4.25kVA maximum during functional test
Operating Temperature Range
+10°C to +30°C
Storage Temperature Range
0°C to +60°
Humidity
0 to 80% relative humidity (non condensing)
Protection
IP43
Case Dimensions
520(w) x 210(h) x 400(d) mm approx.
Weight
E9021, E9022, E9023 E9024V 29kg approx.
E9024 45kg approx.
Vibration, impact and drop rating
BSEN61010
LVD
BSEN61010
EMC
BSEN50081-1
BSEN50082-2
Indicators
Flash meter: 6kV full scale deflection
Status indicators: trip red LED, interlock open red LED, interlock closed green LED, local mode green LED, remote mode green LED
Sockets
Power supply socket: IEC320, 21A
DUT test socket: 400V, 16A 3 phase, neutral and earth IP44
Keyboard: PS2 socket for AT compatible keyboards
Serial Interface (COMM1): 9 way ‘D’ type male connector configured as an RS232 DTE (data terminal equipment)
Serial Interface (COMM2): 9 way ‘D’ male connector configured as an RS232 DCE (data communication equipment)
Control port: 16 way cage clamp connectors 230V AC @ 7A maximum rating
installation category II (IEC664)
Digital port: 16 way cage clamp connectors 12V DC output maximum
External Flash: single pole, latching socket 5kV AC maximum