.jpg)
System Configuration
Options and Accessories
SPC and Data Management
Test Capabilities
Measurement Speed
Test a 500 point net in under 1 second
Auto-start test when product is loaded
Self-learn known good products
Resistance Ranges and Accuracy
Two-wire: 0mW to 2MW at ±2.5% or ±20mW
2MW to 10MW at ±7.0%
10MW to 25MW at ±15%
20MW to 50MW at ±30%
Four-wire: 0mW to 400W at ±2.5% or ±10mW
400W to 2MW at ±2.5% or ±20mW
2MW to 10MW at ±7.0%
10MW to 25MW at ±15%
25MW to 50MW at ±30%
Capacitance Ranges and Accuracy
50pF to 1mF at ±4%
50pF to 10,000mF at ±10%
High Voltage AC
Output Voltage: 50V to 1067V at 1V resolution
Frequency: 50Hz/60Hz
Leakage Current: 5µA to 5mA at 5µA resolution
Capacitance neutralization
Arc detection
Maximum IR: 200 MW
Accuracy: ±12%
High Voltage DC
Output Voltage: 50V to 1500V at 1V resolution
Leakage Current: 1µA to 5mA at 1µA resolution
Arc detection
Maximum IR: 1.5 GW
Accuracy: ±4%
Programmable High Current Source
Output Current: 1mA to 1A at 1mA resolution
Output Voltage: 2V to 28V at 0.1V resolution
Accuracy: ±2.5%
Fixed High Current Source
4-wire Resistance: 1mW to 4W at 0.1mW resolution
Accuracy: ±1.5%, +1mW
Physical Data
Power: 110/220VAC, 50/60 Hz, 1A
Dimensions: 17” L x 9” W x 5” H
Weight: < 20 pounds (128 point unit)